2. |
Machine
Setup and Operation |
- Speed
of invert too great
- Insufficient
parison stretch in blow mold before final blow
- Neck
ring opening too quickly and too wide at transfer
- Parison
not hanging straight in blow mold
- Parison
too soft
- One
neck ring arm set higher than the other
|
|
2. |
Machine
Setup and Operation |
- Correct
speed of invert and final cushioning
- Delay
time of final blow or advance invert
- Adjust
neck ring opening for speed and distance
- Check
parison transferring cleanly into the blow mold
- Increase
counter blow time and/or pressure
- Increase
blank mold contact time and/or blank cooling wind
- Correct
neck ring setting
|
|