2. |
Machine
Setup and Operation |
- Glass
loading too deep into the ring equipment
- Take-out
not correctly adjusted
- Excessive
swabbing
- Blowing
out glass particles when changing mold equipment
- Machine
speed too high
- Mold
equipment incorrectly adjusted on the machine
- Internal
fused or stuck glass particles
- Vacuum
on too soon (blow and blow)
- Plunger
too late
- Glass
in blow head
|
|
2. |
Machine
Setup and Operation |
- Check
loading and machine differential setting
- Reset
take-out tongs
- Reduce
swabbing and use a dry, clean swab
- Always
practice good housekeeping
- Reduce
machine speed
- Check
mold equipment setup
|
|