2. |
Machine
Setup and Operation |
- Incorrect
parison transfer
- Plunger
cylinder incorrectly set
- Excessive
settle blow time
- Bad
loading-poor deflector adjustment
- Dirty
blank
|
|
2. |
Machine
Setup and Operation |
- Check
neck ring setting
- Check
plunger cylinder setting
- Reduce
the settle blow time
- Reset
deflectors and check the gob loading
|
|