2. |
Machine
Setup and Operation |
- Mold
closes too soon or too fast
- Mold
holders are badly worn
- Neck
ring holders bent
- Neck
ring arms not square
- Take-out
tongs close too fast
- Take-out
tongs are wet with oil
- Take-out
tongs are out of line
- Parison
is not setting down in mold so that blowhead pushes finish
downward
- Worn
blank linkage causes one side of blank to go past the center,
setting up a strain as blank opens
- Neck
ring holders set too low on blow mold causing strain on
neck ring during blank opens
- Neck
ring opening too fast
- Plunger
mechanism too high or too low. If plunger is too high it
pushes up the neck ring and causes it to slide against the
blank when opening. If too low, the blank will lift the
neck ring when closing or opening
- Bottom
plate too high or too low
- Too
much cooling wind on the nozzles
- Poor
and irregular mold swabbing
- Offset
mold in top plate
- Invert
to slow-transfer on the fly
- Invert
bouncing over mold
- Blowhead
exhaust, too much finish cooling down before takeover picks
up
- Check
deflection bracket on mold-side
|
|
2. |
Machine
Setup and Operation |
- Adjust
mold closing action
- Check
mold holder for dimensions according to repair data
- Check
neck ring holders to repair drawing dimensions
- Check
invert mechanism with neck ring aligning fixture
- Retard
closing of take-out tongs
- Take-out
tongs should be checked to remove any oil
- Take-out
tongs should be checked for alignment
- Mold
neck to be checked for correct size and shape
- Mold
opening and closing linkage should be renewed
- Check
neck ring, adjust using neck ring setting gauge if necessary
- Adjust
neck ring opening for smoother action
- Check
for relief on mold shoulder radius
- Adjust
the setting of the bottom plate mechanism for correct height
- Reduce
the cooling wind on the molds and check the cooling wind
setup
- Swab
regularly with a clean and dry swab of correct shape
|
|