2. |
Machine
Setup and Operation |
- Neck
ring closing too soon when reverting pinching the finish
- Insufficient
or unequal neck ring opening
- Incorrect
cushioning of invert mechanism on the blow mold side
- Neck
ring opening too hard
- Incorrect
setting of blowhead (out of center)
- End
of outstroke cushioning on take-out incorrect
- Take-out
tongs are out of line or closing too hard
- Incorrect
setting of neck ring over the mold
- Bottom
plate too high
|
|
2. |
Machine
Setup and Operation |
- Retard
neck ring closing
- Increase
neck ring opening
- Adjust
cushioning of invert mechanism
- Adjust
neck ring opening for smoother action
- Adjust
blow head over blow mold
- Adjust
outstroke cushioning of invert mechanism
- Adjust
take-out tongs, allowing them to close slower
- Set
neck ring over blow mold to neck ring setting gauge
- Correct
the bottom plate mechanism setting
|
|