1.
Machine Set-up
Bottom plate too low
Mould open/close speed incorrect
Insufficient Mould Cooling
1.
Machine Set-up
Raise bottom plate to correct height
Adjust mould open/close to
correct speed
Increase Mould Cooling
2.
Mould Equipment
Vertiflow holes too far from cavity
( Hot Moulds )
Damaged Mould
Dirty Moul
2.
Mould Equipment
Refer to Verti-therm for
correct analysis
Change Mould